Monitoring and diagnostics of power transmission lines insulators

Authors

  • А. Г. Галкин
  • Т. А. Несенюк

DOI:

https://doi.org/10.15802/etr.v0i6.24354

Keywords:

insulator, monitoring of insulating structures, device for detecting faults in insulators, base insulator with fault indicators, electromechanical alarm device, RFID-technology

Abstract

In this paper the classification of monitoring and diagnostic methods of insulating structures is made, the peculiarities of noncontact methods application by the example of night observation cameras and thermal imaging cameras are described. The use of the developed “Device for detecting faults in insulators” is suggested. Insulator’s leakage current that detects dielectric’s fault with the help of alarm device is used as operating value. The test results of device operability on surface current and steady leakage current are given. The authors suggest to solve the problem of base insulation diagnostics by setting fault indicators with regard to mechanical, thermal and radio frequency monitoring methods.

References

Несенюк Т. А. Диагностирование изолирующих конструкций // Транспорт Урала.- 2011.- №3 (30). – С. 69-71.

Соловьев Э. П. Выбор наружной полимерной изоляции на основе опыта длительной эксплуатации / Э. П. Соловьев, М. К. Ярмаркин // Газета "Энергетика и промышленность России", №12(64), 2005.

Методические указания по дистанционному оптическому контролю изоляции воздушных линий электропередачи и распределительных устройств переменного тока напряжением 35 – 1150 кВ.

СТО 56947007-29.240.003-2008.

Кочуров Е. Л. О технических характеристиках тепловизоров и о проблемах интерпретации результатов тепловизионной съемки оборудования / Е.Л. Кочуров, И.В. Милютин, А. В. Рубиновский [электрон. ресурс], режим доступа: http://enlab.ru/pub/pub16/pub16.html

Решение Всероссийского семинара «Сравнение различных методов контроля состояния фарфоровых опорно-стержневых изоляторов на подстанциях 110 кВ. Применение методов диагностирования опорно-стержневой изоляции 35-110 кВ», г. Екатеринбург 25.11.2011.

Заявка на изобретение №20121209487(031733) Российской Федерации, МКП 8 Н 01В 17/00. Устройство для определения дефектов в изоляторах. Дата подачи: 22.05.2012.

Протокол испытаний «Устройства для определения дефектов в изоляторах», 2012. – 7 лист.

Заявка на изобретение №20131330627(049422) Российской Федерации, МКП 8 Н 01В 17/14/ Опорный изолятор с индикатором неисправности, дата подачи: 16.07.2013.

Несенюк Т.А. Применение RFID-технологий для поиска неисправной изоляции // Транспорт Ура-ла, 2013. – №2 (37). – С.72-76.

REFERENCES

Nesenuyk T. A. Diagnostirovanie izoliruyushchikh konstruktsiy [Diagnostics of insulating structures] // Transport Urala [Transport of the Urals]. – 2011. – №3 (30). P. 69-71.

Solovyev E. P., Yarmarkin M. K. Vybor naruzhnoy polimernoy izolyatsii na osnove opyta dlitelnoy ekspluatatsii [Selection of exterior polymeric insulation based on long-term operation]. Gazeta "Energetika i promyshlennost Rossii" [Newspaper “ Power and Industry of Russia”], №12(64), 2005.

Metodicheskie ukazaniya po distantsionnomu opticheskomu kontrolyu izolyatsii vozdushnykh liniy elektroperedachi i raspredelitelnykh ustroystv peremennogo toka napryazheniem 35 – 1150 kV.

STO 56947007-29.240.003-2008 [Guidelines for remote optical monitoring of overhead power transmission lines’ insulation and distribution devices of alternate current 35 – 1150 kV].

Kochurov E.L., I.V. Milyutin, Rubinovskiy A.V. O tekhnicheskikh kharakteristikakh teplovizorov i o problemakh interpretatsii rezultatov teplovizionnoy syemki oborudovaniya [On the specification of thermal imaging cameras and interpretation problems of equipment thermal-imaging shooting], URL: http://enlab.ru/pub/pub16/pub16.html

Sravnenie razlichnykh metodov kontrolya sos-toyaniya farforovykh oporno-sterzhnevykh izolyatorov na podstantsiyakh 110 kV. Primenenie metodov diagnostirovaniya oporno-sterzhnevoy izolyatsii 35-110 kV. [Resolution of All-Russian seminar “Comparison of different monitoring methods of porcelain rigid-rod insulators at 110 kV substations. Application of diagnostic methods of 35-110 kV rigid-rod insulation], Ekaterinburg, 25.11.2011

Application for an invention No.20121209487 (031733) of the Russian Federation, MKP 8 N 01V 17/00. Ustroystvo dlya opredeleniya defectov v izolatorakh [A device for detecting faults in isolators] / T.A. Nesenyuk. Filing date 22.05.2012

Protokol ispytaniy «Ustroystva dlya opredeleniya defektov v izolyatorakh» [Test record sheet A device for detecting faults in isolators], 2012, 7 p.

Application for an invention No. 20131330627 (049422) of the Russian Federation, MKP 8 N 01V 17/14/] Oporny izolyator s indikatorom neispravnosti [Base insulator with fault indicator], Filing date 16.07.2013.

Nesenuyk T. A. Primenenie RFID-tekhnology dlya poiska neispravnoy izolyatsii [The use of RFID-technology to detect insulation faults ] //Transport Urala [Transport of the Urals], 2013.- №2 (37). P.72-76.

Published

2014-05-06

Issue

Section

Automation and Diagnose