Contact network monitoring
DOI:
https://doi.org/10.15802/etr.v0i5.24328Keywords:
contact network, monitoring, diagnostics, safetyAbstract
The paper presents monitoring devices, and diagnostics contact network PAMAR SMD. The task of monitoring is to gather information from all the territory and a graphical representation of the network on the monitor. In addition, you can access to detailed data on supply voltage, temperature, humidity, level and status of all systems of input / output. The procedures for trial operation, the results of operation of the system in different temperature conditions. It is shown that the diagnostic and monitoring vandal contact network provides a greater degree of safety of railway traffic and subsequently transported for the safety of passengers and cargo. Its use can improve economic performance because it reduces the cost of restoring the contact system and the level of compensation for late trains.References
Młyńczak J., Pawelak M.: Sposób kontroli zmian naprężenia sieci trakcyjnej napowietrznej i układ kontroli zmian naprężenia sieci trakcyjnej napowietrznej, Zgłoszenie Patentowe P.390149, 2010
Mikulski J., Młyńczak J., Pawelak M.: Ochrona antykradzieżowa sieci trakcyjnej. W: Computer systems aided science and engineering work in transport, me-chanics and electrical engineering. TRANSCOMP2010. 14th International conference, Zakopane, Poland, 6 XII - 9 XII 2010. Conference proceedings. [Dokument elektroniczny]. Logistyka 6/2010, Poznań: Instytut Logistyki i Magazynowania, 2010, dysk optyczny (CD-ROM) s. 2257-2265, bibliogr. 5 poz.
Młyńczak J., Pawelak M.: Monitoring sieci trakcyjnej. Infrastruktura Transportu 2012 nr 5, s. 56-59, bibliogr. 1 poz.
Andrzej Białoń „Attenuation measurements of overvoltages on contact Line” Springer Verlag Berlin Heidelberg Seria: Telematics in the Transport Environment 12th International Conference on Transport Sys-tems Telematics, TST 2012, Katowice-Ustron, Poland, October 10-13, 2012, Selected PapersSeries: Commu-nications in Computer and Information Science, Vol. 329 angielski 2012.
Andrzej Białoń, Juliusz Furman Research damp-ing surges In contact network 3 kV DC Elektrifikacija transporta Ukraina 3/2012 rosyjski s. 35-39.
Andrzej Białoń, Juliusz Furman Surgest tests conducted in the contact system I lab environment Elektrifikacija transporta Ukraina 3/2012 rosyjski s. 39-43.
Downloads
Published
Issue
Section
License
При направленні статті в редакцію, автор гарантує, що стаття надається для публікації уперше і раніше не була опублікована в інших виданнях повністю або частково.
Підписанням ліцензійного договору автор(и) підтверджує(ють), що має(ють) виняткове авторське право на статтю і передає(ють) невиняткові права на свою статтю видавництву журналу «Електрифікація транспорту» для публікації в черговому номері журналу. Автор(и) так само дає(ють) згоду на передачу і розміщення електронної версії своєї статті на сайтах баз даних, створюваних і поширюваних через Інтернет.